Clinical waste incinerator

Email:sales@hiclover.com|Tel:+86-25-8461 0201

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Diesel Oil Consumption (kg/hour) 8.4 10.9 13.3 16.9
Natural Gas Consumption (m3n/hour) 10.1 13 16 20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm

Lilongwe, Mzuzu and Blantyre Rotary kiln type
Load Capacity 500 – 1000kg 
Burn rate – 200kg/hr CAPACITY
Fuel – Diesel  MAIN SOURCE
LPG GAS IGNITER
ELECTRICITY: to run motors,fans,& controllers 
THE System should be energy efficient 
Average Fuel Consumption 5 -10 (liters/hr) 
Auto ignition 
Automatic control and temperature Monitoring
Primary Chamber&POST COMBITION CHAMBERS: Minimum temperature should be 800 degrees celcius
Secondary and Primary Chambers 
POST COMBUSTION CHAMBER Residence time – two(2) seconds
Oxygen content of the emmited gasses shall not be less than 11%
Chimney:
The maximum exit velocity of the emissions shall not be less 10 meters per second
The stack should be insulated to maintain maximum outlet temperature
Sampling platform and port for measurement of emmissions shall be provided*MINIMUM of 18 METERS above ground provided with COMBSTION GAS  ANALYSER  measuring probe for capturing the GAS SAMPLE at the chimney & capable of measuring CO, NOx &SO2
External Dimensions 
Length – 2.5 – 3.0m, Width – 
1.0 – 1.2m, Height – 3.0 – 4.0m
Door Opening (mm) from 750×750- 1000 x 1670 
Casing 5mm mild steel plate fully insulated 
Minimum Temperatures 1300 – 1500 oC 
Maximum Temperatures 1300-1500 oC 
Control Panel 
Dense/heavy duty Refractory concrete lining for maximum heat retention rated to 1500 – 1700 oC 
Solid Hearth Support 
Ashing Door –USER FRENDLY ASH COLLECTING SYSTEM
Loading Door 
Fire Gate

HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.



 

2020-07-07